The Hydra Mechanism — What Sets It Apart
Standard microneedling creates channels. The H24 goes further. Its 24-needle head delivers serum through micro-channels directly into the skin during the needling motion — not applied on top afterward. The serum follows the needle path in real time, uniformly reaching varying skin depths along the central axis and at 24 discharge points. The result is more consistent absorption, better coverage, and measurably improved outcomes across multiple skin concerns.
This makes the H24 particularly effective when paired with targeted treatment serums — a strong upsell opportunity for clinics retailing serums alongside devices.
Adjustable Depth — One Device, Multiple Protocols
The built-in adjustment knob offers four needle depth settings:
- 0.25mm — Surface-level exfoliation, serum absorption, glow treatments
- 0.50mm — Fine lines, mild pigmentation, skin texture refinement
- 1.0mm — Acne scarring, deeper wrinkles, pore reduction
- 1.5mm — Advanced resurfacing, collagen induction, skin laxity
This range makes the H24 versatile enough to support multiple treatment protocols, reducing your inventory complexity while expanding your service offering.
Clinical Applications
The H24 addresses a broad spectrum of skin concerns your clients are actively seeking solutions for:
Oily and acne-prone skin, post-acne pitting and residual marks, uneven skin tone and pigmentation, including chloasma, enlarged pores, fine lines and crow’s feet, surface wrinkles, skin laxity and loss of firmness, dryness, peeling and dull complexion, compromised skin barrier function, and thinning hair when used with growth-stimulating serums.
How to Use — Treatment Protocol
- Fully disinfect the stamp prior to every session — sterility is non-negotiable
- Cleanse skin thoroughly, removing all makeup and surface residue
- Fill the 10ml serum cartridge — hyaluronic acid is recommended, though any targeted serum applies
- Stamp across the treatment area in horizontal, vertical, and diagonal passes — 4 to 5 passes per direction
- Maintain consistent speed and pressure throughout for uniform results
Advise clients to replace the needle head every 15 uses or every 3 months — whichever comes first. Full sterilization before each use is mandatory.
Device Specifications
- 24 micro-needles per head
- Adjustable depth: 0.25 / 0.50 / 1.0 / 1.5mm
- 10ml integrated serum cartridge
- Hypoallergenic, non-slip ergonomic body
- Suitable for the face and scalp
























